Cancellation of a Non-Credible Contingency Event: Collinsville North - Proserpine No.7125 132 kV line and Collinsville North - Proserpine No.7126 132 kV line in QLD1 due to Lightning.
Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.
Region: QLD1
Lines: Collinsville North - Proserpine No.7125 132 kV and Collinsville North - Proserpine No.7126 132 kV
Cancellation time: 15/12/2024 14:34
Constraint set(s) revoked:
NONE
Refer AEMO Electricity Market Notice 121958
Auto-generated on behalf of Manager NEM Real Time Operations
STPASA - Update of the Forecast Lack Of Reserve Level 1 (LOR1) in the NSW Region on 17/12/2024
The Forecast LOR1 condition in the NSW region advised in AEMO Electricity Market Notice No. 121899 has been updated at 1430 hrs 15/12/2024 to the following:
[1.] From 1400 hrs 17/12/2024 to 1430 hrs 17/12/2024.
The forecast capacity reserve requirement is 1430 MW.
The minimum capacity reserve available is 1307 MW.
[2.] From 2130 hrs 17/12/2024 to 2230 hrs 17/12/2024.
The forecast capacity reserve requirement is 1859 MW.
The minimum capacity reserve available is 1203 MW.
AEMO Operations
Reclassification of a Non-Credible Contingency Event: Collinsville North - Proserpine No.7125 132 kV line and Collinsville North - Proserpine No.7126 132 kV line in QLD1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: QLD1
Lines: Collinsville North - Proserpine No.7125 132 kV and Collinsville North - Proserpine No.7126 132 kV
Duration: 15/12/2024 13:32 until further notice
Constraint set(s) invoked:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations
Reclassification of a Non-Credible Contingency Event: Strathmore - Clare South No.7208 132 kV line and Strathmore - Clare South tee King Creek No.7128 132 kV line in QLD1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: QLD1
Lines: Strathmore - Clare South No.7208 132 kV and Strathmore - Clare South tee King Creek No.7128 132 kV
Duration: 15/12/2024 13:11 until further notice
Constraint set(s) invoked:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations
[EventId:202412151235_confirmed] Prices for interval 15-Dec-2024 12:35 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1300 hrs on 15 December 2024
PRICES ARE NOW CONFIRMED for trading interval 15-Dec-2024 12:35.
In accordance with Market Notice 121942 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202412151300_confirmed] Prices for interval 15-Dec-2024 13:00 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1300 hrs on 15 December 2024
PRICES ARE NOW CONFIRMED for trading interval 15-Dec-2024 13:00.
In accordance with Market Notice 121950 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202412151255_confirmed] Prices for interval 15-Dec-2024 12:55 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1300 hrs on 15 December 2024
PRICES ARE NOW CONFIRMED for trading interval 15-Dec-2024 12:55.
In accordance with Market Notice 121948 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202412151250_confirmed] Prices for interval 15-Dec-2024 12:50 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1300 hrs on 15 December 2024
PRICES ARE NOW CONFIRMED for trading interval 15-Dec-2024 12:50.
In accordance with Market Notice 121946 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202412151245_confirmed] Prices for interval 15-Dec-2024 12:45 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1300 hrs on 15 December 2024
PRICES ARE NOW CONFIRMED for trading interval 15-Dec-2024 12:45.
In accordance with Market Notice 121945 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.