Reclassification of a Non-Credible Contingency Event: Strathmore - Clare South No.7208 132 kV line and Strathmore - Clare South tee King Creek No.7128 132 kV line in QLD1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: QLD1
Lines: Strathmore - Clare South No.7208 132 kV and Strathmore - Clare South tee King Creek No.7128 132 kV
Duration: 04/03/2025 17:06 until further notice
Constraint set(s) invoked:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations
Reclassification of a Non-Credible Contingency Event: Collinsville - Stoney Creek 7306 132KV LINE line and Collinsville - Newlands 7121 132KV LINE line in QLD1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: QLD1
Lines: Collinsville - Stoney Creek 7306 132KV LINE and Collinsville - Newlands 7121 132KV LINE
Duration: 04/03/2025 16:16 until further notice
Constraint set(s) invoked:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations
Reclassification of a Non-Credible Contingency Event: Collinsville North - Proserpine No.7125 132 kV line and Collinsville North - Proserpine No.7126 132 kV line in QLD1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: QLD1
Lines: Collinsville North - Proserpine No.7125 132 kV and Collinsville North - Proserpine No.7126 132 kV
Duration: 04/03/2025 15:59 until further notice
Constraint set(s) invoked:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region NSW1 Tuesday, 4 March 2025
NON-CONFORMANCE NSW1 Region Tuesday, 4 March 2025
AEMO has declared the following unit as non-conforming under clause 3.8.23 of the National Electricity Rules:
Unit: WTAHB1
Duration: 04/03/2025 11:55 to 04/03/2025 12:00
Amount: -33 MW
Constraint: NC-N_WTAHB1
Auto-generated on behalf of Manager NEM Real Time Operations
[EventId:202503041020_confirmed] Prices for interval 04-Mar-2025 10:20 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1040 hrs on 4 March 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Mar-2025 10:20.
In accordance with Market Notice 125234 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202503041040_confirmed] Prices for interval 04-Mar-2025 10:40 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1040 hrs on 4 March 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Mar-2025 10:40.
In accordance with Market Notice 125240 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202503041035_confirmed] Prices for interval 04-Mar-2025 10:35 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1040 hrs on 4 March 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Mar-2025 10:35.
In accordance with Market Notice 125238 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202503041030_confirmed] Prices for interval 04-Mar-2025 10:30 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1040 hrs on 4 March 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Mar-2025 10:30.
In accordance with Market Notice 125236 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202503041025_confirmed] Prices for interval 04-Mar-2025 10:25 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1040 hrs on 4 March 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Mar-2025 10:25.
In accordance with Market Notice 125235 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.